  1.                          SECTION 09985
  2.  
  3.                       MASONRY STAIN SYSTEM
  4.  
  5. NOTE ** Rainguard Products Company, masonry stain system.
  6. NOTE **
  7. NOTE ** This section is based on the products of Rainguard
  8.         Products Company, which is located at:
  9. NOTE **    3471 Via Lido
  10. NOTE **    Suite 213
  11. NOTE **    Newport Beach, CA  92663
  12. NOTE **    Tel:  (888) 765-7070
  13. NOTE **    Fax:  (949) 675-3450
  14. NOTE **    Website:  www.rainguard.com
  15. NOTE **
  16. NOTE ** Rainguard Products Company manufactures coatings
  17.         for the construction trades.  See their other
  18.         sections for graffiti-resistant coatings and
  19.         elastomeric wall coatings.
  20. NOTE **
  21. NOTE ** SECTION 09985 - MASONRY STAIN SYSTEM, Copyright
  22.         1998, The Architect's Catalog, Inc.
  23.  
  24. PART 1  GENERAL
  25.  
  26. 1.1 SECTION INCLUDES
  27. NOTE ** Select paragraph below as applicable to project;
  28.         add other paragraphs as required for project.
  29.  
  30.     A.  Masonry stain system, comprised of water repellent and
  31.         masonry stain; exterior elevations.
  32.  
  33.     B.  Masonry stain system, comprised of water repellent and
  34.         masonry stain; interior elevations.
  35.  
  36.     C.  _______________________________________.
  37.  
  38. 1.2 RELATED SECTIONS
  39. NOTE ** Delete sections below not relevant to this project;
  40.         add others as required.
  41.  
  42.     A.  Section 03300 - Cast-In-Place Concrete.
  43.  
  44.     B.  Section 03400 - Precast Concrete.
  45.  
  46.     C.  Section 04810 - Unit Masonry Assemblies.
  47.  
  48.     D.  Section 07140 - Fluid-Applied Waterproofing.
  49.  
  50.     E.  Section 07190 - Water Repellents.
  51.  
  52.     F.  Section 07900 - Joint Sealers.
  53.  
  54.     G.  Section 07920 - Joint Sealants.
  55.  
  56.     H.  Section 09220 - Portland Cement Plaster.
  57.  
  58.     I.  Section 09900 - Paints and Coatings.
  59.  
  60.     J.  Section 09930 - Stains and Transparent Finishes.
  61.  
  62.     K.  Section 09960 - High-Performance Coatings.
  63.  
  64.     L.  Section 09980 - Coatings for Concrete and Masonry.
  65.  
  66.     M.  Section _____ - _________________________.
  67.  
  68. 1.3 SYSTEM DESCRIPTION
  69.  
  70.     A.  Masonry stain system specified herein is a penetrating,
  71.         permanent, non-fading liquid solution, resisting
  72.         ultraviolet light degradation, flaking, or peeling from
  73.         the substrate, and allowing moisture vapor transmission.
  74.         The system shall not appreciably change the masonry
  75.         surface texture or leave a glossy finish.
  76.  
  77.     B.  Liquid water repellents specified herein are clear, deep-
  78.         penetrating, non-film forming, non-silicone, non-
  79.         yellowing chemical solutions.
  80.  
  81. 1.4 SUBMITTALS
  82.  
  83.     A.  Submit under provisions of Section 01300.
  84.  
  85.     B.  Product Data:  Three copies of manufacturer's current
  86.         technical data sheets for materials.
  87. NOTE ** Delete the following paragraph if samples are not
  88.         required.
  89.  
  90.     C.  Samples:
  91.         1.  Opaque:  One draw down of each specified color.
  92.         2.  Semi-Transparent:  Substrate with two transparent
  93.             variations.
  94.  
  95. 1.5 QUALITY ASSURANCE
  96.  
  97.     A.  Installer Qualifications:  Minimum five years experience
  98.         regularly engaged and specializing in the application of
  99.         specialty surface treatments to exterior wall substrates.
  100.  
  101.     B.  Pre-Installation Meetings:
  102.         1.  Before Application:  Installer and Manufacturer's
  103.             Representative shall inspect surfaces to be treated,
  104.             noting in writing to the Architect, deficiencies or
  105.             flaws in the substrate construction which would
  106.             affect the performance or appearance of the masonry
  107.             stain.
  108.         2.  Beginning of Application:  Manufacturer's
  109.             Representative shall assure utilization of proper
  110.             equipment, verify material quantities, and supervise
  111.             material application techniques upon a substantial
  112.             wall section.  This wall section shall act as a
  113.             comparative standard for the project.
  114.  
  115.     C.  Installer shall not proceed with material application
  116.         until all deficiencies noted in pre-application
  117.         inspection report have been corrected.
  118.  
  119.     D.  Installer shall notify manufacturer no less than 3 days
  120.         before starting application.
  121.  
  122. 1.6 DELIVERY, STORAGE, AND HANDLING
  123.  
  124.     A.  Deliver materials in original sealed containers, clearly
  125.         marked with manufacturer's name, type of material, and
  126.         batch number.
  127.  
  128.     B.  Inspect the materials upon delivery to assure that
  129.         specified products have been received.
  130.  
  131.     C.  Store materials where temperatures are not less than 45
  132.         degrees F (7 degrees C).
  133.  
  134.     D.  Use all means necessary to protect material before,
  135.         during, and after installation, and to protect work of
  136.         other trades.
  137.  
  138. 1.7 ENVIRONMENTAL REQUIREMENTS
  139.  
  140.     A.  Comply with current Federal and State environmental
  141.         requirements.
  142. NOTE ** Delete the following article if no warranties are
  143.         required, or if work is covered under the terms of
  144.         a general project warranty specified elsewhere.
  145.         You may edit the article to obtain a warranty from
  146.         the Contractor only, or to suit other project-
  147.         specific criteria.
  148.  
  149. 1.8 WARRANTY
  150.  
  151.     A.  Manufacturer Warranty:  Supply materials manufacturer's
  152.         warranty against water intrusion, flaking, or peeling.
  153. NOTE ** Contact manufacturer for warranty period based on
  154.         project requirements and select appropriate
  155.         subparagraph below.
  156.         1.  Warranty Period:  Five years from date of Substantial
  157.             Completion.
  158.         2.  Warranty Period:  Ten years from date of Substantial
  159.             Completion.
  160.  
  161.     B.  Installer Warranty:  Warrant workmanship for a period of
  162.         two years from the date of Substantial Completion.
  163.  
  164.  
  165. PART 2  PRODUCTS
  166.  
  167. 2.1 MANUFACTURERS
  168.  
  169.     A.  Acceptable Manufacturer:  Rainguard Products Company;
  170.         3471 Via Lido, Suite 213, Newport Beach, CA 92663:  ASD.
  171.         Tel: (888) 765-7070; Fax: (949) 675-3450; Website:
  172.         www.rainguard.com
  173.  
  174.     B.  Requests for substitutions will be considered in
  175.         accordance with provisions of Section 01600.
  176.  
  177. 2.2 MATERIALS
  178. NOTE ** Consult with manufacturer for choice of masonry
  179.         stain based on project requirements; select
  180.         appropriate paragraph below.
  181.  
  182.     A.  Masonry Stain:  Rainguard "Color-Lok opaque stain."
  183.  
  184.     B.  Masonry Stain:  Rainguard "Color-Lok semi-transparent"
  185.         stain.
  186. NOTE ** Consult with manufacturer for choice of water
  187.         repellent based on project requirements; select
  188.         appropriate paragraph below.
  189.  
  190.     C.  Water Repellent:  Rainguard "Blok-Lok with Micro-Lok"
  191.         (V.O.C. compliant).
  192.  
  193.     D.  Water Repellent:  Rainguard "XS with Micro-Lok" (solvent
  194.         base).
  195.  
  196.     E.  Water Repellent:  Rainguard "Regular" with Micro-Lok
  197.         (V.O.C. compliant-water based).
  198.  
  199.     F.  Water Repellent:  Rainguard "Super" with Micro-Lok
  200.         (V.O.C. compliant-water based).
  201.  
  202.     G.  Water Repellent:  Rainguard "HD" with Micro-Lok (solvent
  203.         base).
  204.  
  205.     H.  Water Repellent:  Rainguard "STD" with Micro-Lok (solvent
  206.         base).
  207.  
  208.     I.  Water Repellent:  Rainguard "STD-E" or "HD-E" or "XS-E"
  209.         with Micro-Lok (V.O.C. compliant-solvent base).
  210.  
  211.  
  212. PART 3  EXECUTION
  213.  
  214. 3.1 EXAMINATION
  215.  
  216.     A.  Verify that surfaces to be coated are in proper
  217.         condition.
  218.         1.  New substrates: Cured 30 days before application.
  219.         2.  Cured substrates:  Allowed to dry three to seven days
  220.             in clear warm weather following rainfall before
  221.             application.
  222.         3.  Substrate moisture content:  No higher than 15
  223.             percent as registered on an electronic moisture
  224.             meter.
  225.  
  226.     B.  Verify that voids in masonry joints or joints found to be
  227.         unsound or defective have been raked out and pointed with
  228.         mortar to create a joint of full-face shell thickness.
  229.  
  230.     C.  Where freezing conditions exist before application, allow
  231.         adequate time for building to thaw.
  232.  
  233. 3.2 PREPARATION
  234.  
  235.     A.  Thoroughly clean substrates of foreign substances, such
  236.         as dirt, efflorescence, and mortar spills.
  237.         1.  Use "dry" cleaning method where practicable.
  238.         2.  Allow three days minimum dry time in warm weather
  239.             before applying material if wet cleaning method is
  240.             utilized.
  241.  
  242.     B.  Protect windows and work of other trades against damage
  243.         by coating, whether to be coated or not.
  244.  
  245.     C.  Protect plant life against damage from coatings.
  246.  
  247. 3.3 APPLICATION
  248.  
  249.     A.  Apply materials in strict accordance with manufacturer's
  250.         recommendations and when substrate surface temperature is
  251.         between 45 and 90 degrees F (7 and 32 degrees C).
  252.         1.  Follow instruction in manufacturer's current
  253.             technical data sheet for general information and
  254.             coverage rates.
  255.  
  256.     B.  Spray apply water repellent using high-volume, low-
  257.         pressure spray equipment; allow to cure 24 hours before
  258.         application of masonry stain.
  259.  
  260.     C.  Spray apply masonry stain using airless spray equipment.
  261.  
  262.     D.  Clean all drips, runs, and overspray residue while still
  263.         wet.
  264.  
  265. 3.4 FIELD QUALITY CONTROL
  266.  
  267.     A.  Manufacturer's Representative shall inspect all treated
  268.         surfaces after work is complete to verify proper
  269.         application.
  270.  
  271. 3.5 ADJUSTING AND CLEANING
  272.  
  273.     A.  If damage occurs, immediately make all repairs and
  274.         replacements necessary at no additional cost to Owner.
  275.  
  276.     B.  During process of work, remove discarded materials,
  277.         rubbish, cans, and rags at end of each workday.
  278.  
  279.     C.  Correct any damage by cleaning and repairing or
  280.         replacing, as acceptable to Architect.
  281.  
  282.  
  283.                          END OF SECTION
  284.